language
   
SISTEMA DI CONFRONTO

FLK TECH

SISTEMI DI CONTROLLO

Home  >>  Controllo processo  >>  Sicurezza industriale
Correlati alla sicurezza

Programmable Logic Controller (PLC)

No. Manufacturer Product title Main marketing
area:
Geographical/
Customer
Main marketing
area:
area of businnes/
processes
Possible system structures AK Fault tollerance with/without time limit (specialities)
1. ABB Industri AS Advant Safeguard 400 World-wide Chemical, Petro-chemical, Off-shore, BMS 1oo1D
1oo2D
4,SIL2
6,SIL3
 
2. ABB Industri (former August Systems) CS386 Triguard SC300E World-wide Chemical, Petro-chemical, Off-shore, BMS 2oo3
2oo3
6
6
AK5 without
3. ICS Triplex Regent
Trusted ICS (TMR,RISC-µP)
Middle East, Russia, USA, Latin America Petro-chemical, in Off-shore Nr.1 2oo3
2oo3
5
6
without
AK5 without
4. SIEMENS Moore Process Automation Quadlog World-wide Chemical, Off-Shore, FPSO 1oo1D
1oo2D
1oo2D
4
5
6
without
with 72h, with 1h
5. SIEMENS AG S5-95F
S5-115F
S7-400F
S7-400FH
world-wide
all
all
all
1oo2
1oo2
1oo1, 1oo2 CPU, I/O
2oo2, 2oo2 CPU, I/O
6,SIL3?
6
SIL3
SIL3
0 h
0 h
0 h
without
6. SMS
(Honeywell)
FSC100,101
FSC102
FSC202
FSC new CPU with QMRÔ
world-wide
(>1200 systems)
Chemical,
Petro-chemical,
Off-Shore, BMS
1oo2D
1oo2D
2oo2D
2oo4D
4
5
6
6, SIL3
without
72 h
1 h
without(no cert.)
7. TRICONEX
FoxGuard
(Foxboro/Eckardt)
TRICON V.6,7
TRICON V.>7-10
TRIDENT
world-wide
(>2000 systems)
Exxon, Shell,Elf
Chemical,
Petro-chemical,
Off-Shore, BMS
2oo3
2oo3
2oo3
5
6
6,SIL3
AK5 without
8. YISS(Yokogawa
Industrial Safety
System bv)
(former GTI)
ProSafe-DSP
PLS (former
GTI)ProSafe-PLC
(same system as
SIEMENS
Moore!)
world-wide
NAM, Shell
Petro-chemical, Off-Shore 1oo2
2oo3
1oo1D
1oo2D
6
6
4
6
without
with
9. HIMA H41q/H51q-MS
H41q/H51q-HS
H41q/H51q-HRS
world-wide
(>4000 systems)
Chemical,
Petro-chemical,
Off-Shore, BMS
2oo2
2oo4
2oo4
6
6
6
without
without
without

System structure PLC

No. Fault-free syste Degradation 1 Degradation 2 System structure
1. 2oo4 (2von4) 1oo2 (2von2) Shutdown Safety related and fault tolerant
2. 1oo3 (3von3) Shutdown   Safety related
3. 2oo3 (2von3) 1oo2 (2von2) Shutdown Safety related and fault tolerant
4. 1oo2D (2von2D) 1oo1D (1von1D) Shutdown Safety related and fault tolerant with time restriction
5. 1oo2 (2von2) Shutdown   Safety related
6. 2oo2 (1von2)) 1oo1 (1von1) Shutdown Safety related and fault tolerant with time restriction
5. 1oo1 (1von1) Shutdown   Safety related
* PLC with high diagnostic coverage (D)
  


Servizio clienti
Supporto
Dove siamo
Notizie legali
Privacy
Mappa del sito
FLKTech d.o.o
VAT št.:SI95979433 / Matična številka:9550020000
SIMONITIJEVA ULICA 15, 1000 LJUBLJANA
email: info(at)flktech.com
© 2024 Copyright FLK Tech